5.1 Sense Data

C141-E167

5 - 7

Table 5.2

Sense and subsense codes (2 of 5)

C*

Q*

Name

Explanation

Sense

key

13

00

Sync Byte not found for
Data field

SB (Sync Byte) could not be detected in the Data area.

1, 3, B

14

00

Record entity not found

Expected data from a sector was undetected. (LBA compare error
detected by FMT)

1, 3, B

01

Record not found

The target data block (sector) could not be detected.

3, B

01

Mechanical positioning
Error

A seek error occurred in the drive.

1, 3, B

15

02

Positioning Error detected
by read of medium

LBA did not match due to Cylinder number’s mismatch.

1, 3, B

01

Recovered data with retries A data error was recovered from by reading was retried.

1

02

Recovered data with
positive head offset

A data error was recovered by read retry with offsetting head to
positive direction.

1

03

Recovered data with
negative head offset

A data error was recovered by read retry with offsetting head to
negative direction.

1

06

Recovered data without
ECC: data auto-
reallocated

Automatic alternate allocation was applied without ECC correcting a
data error.

1

17

08

Recovered data without
ECC: recommended
rewrite

Rewriting to the same sector was performed without ECC correcting
a data error.

1

02

Defect list error in primary
list

An error was detected during reading of the defect list (P List).

3

03

Defect list error in grown list An error was detected during reading of the defect list (G List).

3

80

Log information read error

An error was detected during reading of statistical information.

3

81

Log information write
error

A write error was detected during writing of statistical information.

3

82

Drive Parameter SA read
Error

An error was detected during reading of SA information (Device
Information)

3

83

Drive Parameter SA write
Error

An error was detected during writing of SA information (Device
Information)

3

19

84

Mode Select SA write
Error

An error was detected during writing of SA information (Mode
Select Paramenter)

3

1A

00

Parameter list length error There is a mistake in the indication of the parameter list page length.

5

01

Primary defect list not found The defect list (P List) header is incorrect.

3

02

Grown defect list not found

The defect list (G List) header is incorrect.

3

1C

90

SA information list not
found

The SA information (MODE SELECT parameter) header is
incorrect.

3

00

Miscompare during verify
operation

Comparison of data transferred from the INIT by a VERIFY
command (when the Byte Check mode was specified) with data read
from the disk media was terminated unsuccessfully.

E

E

1D

80

Miscompare during self-
configuration

There is an unmatch to compare read data with write data during
self-configuration.

* C: Sense Code, Q: Sub-sense Code