Parameter Data Formats

4 - 44

C141-E167

4.2.4.1 Read errors recovered without delays (Page 03, Code 0000)

Bit
Byte

7

6

5

4

3

2

1

0

4

5

(MSB)

X'0000' (Parameter code)
(Errors Recovered Without Delays)

(LSB)

DU

DS

TSD

ETC

TMC

LBIN

LP

6

0

0

0

0

0

0

0

0

7

X'04' (Parameter Length)

8

(MSB)

9

10

Counter Value

11

(LSB)

The Counter Value indicates the count of all recovered read errors that would not be reported to the
initiator during read operations, because no delay is incurred.

4.2.4.2 Read errors recovered with possible delays (Page 03, Code 0001)

Bit
Byte

7

6

5

4

3

2

1

0

4

5

(MSB)

X'0001 (Parameter code)
(Errors Recovered With Possible Delays)

(LSB)

DU

DS

TSD

ETC

TMC

LBIN

LP

6

0

0

0

0

0

0

0

0

7

X'04' (Parameter Length)

8

(MSB)

9

10

Counter Value

11

(LSB)

The Counter Value indicates the count of all recovered read errors that would not be reported to the
initiator during read operations, because possible delay is incurred.