beautypg.com

FUJITSU MAS3367 User Manual

Page 108

background image

Command Specifications

3 - 46

C141-E167

(1)

Page code

This field indentifies which log page is being transferred.

The log pages that can be transferred by this command are shown below.

Page Code

Description

Changable Parameter

01

Buffer Overrun / Underrun Page

Disable

02

Write Error Counter Page

Enable

03

Read Error Counter Page

Enable

05

Verify Error Counter Page

Enable

06

Non-medium Error Page

Enable

0D

Tempature Page

Disable

0E

Start-stop Cycle Counter Page

Enable only 0002

0F

Application Client Log Page

Enable

10

Self-Test Result Log Page

Disable

(2)

Page length

This field specifies the length in bytes of the following log parameters. If the application client sends
a page length that results in the truncation of any parameter, the device server terminates the
command with CHECK CONDITION status (ILLEGAL REQUEST [=5] / Invalid field in paramter
list [=26-00]).

The log pages contain one or more special data structures called log parameters as shown below. Each log
paramter begins with a 4-byte parameter header followed by one or more bytes of "Parameter Value" data.

Bit
Byte

7

6

5

4

3

2

1

0

0

Parameter Code (MSB)

1

Parameter Code (LSB)

2

DU

DS

TSD

ETC

TMC

LBIN

LP

3

Parameter Length

4

n

Parameter Value

~

~

~