5.1 Sense Data

C141-E167

5 - 5

Table 5.1

Sense key

Sense

Key

Name

Explanation

0

NO SENSE

The specific sense key does not exist.

1

RECOVERED
ERROR

1) Indicates that the command which was executed last was terminated

normally with a recovery operation by the IDD. If multiple errors
which were successfully recovered from during processing of a
single command occurred, the last error to have occurred is
reported.

2) Rounding processing of the MODE SELECT parameter was

performed.

2

NOT READY

The disk drive is not in a state where it can be accessed.

3

MEDIUM
ERROR

An irrecoverable error was detected due to a defect in the disk media or
an error in the recorded data.

4

HARDWARE
ERROR

The IDD detected an error in the hardware for which recovery processing is
impossible during command execution or self-diagnosis.

5

ILLEGAL
REQUEST

An illegal value was detected in the parameter transferred in the CDB or
the specification in the command. Also, an error in the LUN
specification. If the IDD detects an illegal parameter in the CDB, it
terminates the command without changing the contents of the disk
media. If an illegal parameter is detected in the parameters transferred
from the INIT in the DATA OUT phase, the contents of the disk media
may be changed by that command.

6

UNIT
ATTENTION

A UNIT ATTENTION condition occurred. (See Section 1.5 concerning
details of the UNIT ATTENTION condition.)

7

DATA
PROTECT

1) An illegal operation was attempted in an area where a read or write

operation is prohibited. In this case, that command is not executed.

2) A SET LIMITS command was issued 2 times in a group of

commands linked in a series.

8

BLANK CHECK

Not Used

9

(Reserved)

Not Used

A

COPY ABORTED

Not Used

B

ABORTED
COMMAND

The IDD terminated a command abnormally during execution. Normally,
the INIT can attempt to recover by reissuing that command.

C

EQUAL

Not Used

D

VOLUME
OVERFLOW

Not Used

E

MISCOMPARE

During execution of a Byte Check with the VERIFY command, the data
transferred from the INIT were compared to the data read from the disk
drive, but they did not match.

F

(Reserved)

Not Used