HEAT PUMP ROOM AIR CONDITIONERS: TROUBLE SHOOTING TIPS

ELECTRICAL TROUBLESHOOTING CHART - HEAT PUMP

Reversing Valve Stuck

Replace the Reversing Valve

Replace the Solenoid Coil

NO

Is the Solenoid Coil Good?

Is Line Voltage

Present at the Solenoid

Is the Selector Switch

Set for Heat?

NO

SYSTEM COOLS WHEN

HEATING IS DESIRED.

YES

HEAT PUMP

YES

Noncondensables (air)

in System

Overcharged

Low Airfl ow Across

Indoor Coil

Outdoor Ambient Too High

For Operation In Heating

Moisture in System

Defective Compressor

Defective Compressor

Undercharged

Overcharged

Undercharged

Refrigerant System

Restriction

Reversing Valve not

Fully Seated

Low Airfl ow

Across Outdoor Coil

Outdoor Ambient Too High

for Operation in Heating

Refrigerant System

Restriction

Reversing Valve not

Fully Seated

REFRIGERANT SYSTEM DIAGNOSIS - HEATING CYCLE

LOW SUCTION PRESSURE

HIGH SUCTION PRESSURE

LOW HEAD PRESSURE

HIGH HEAD PRESSURE