COOLING ONLY ROOM AIR CONDITIONERS: TROUBLESHOOTING TIPS

Possible Solution

e

s

u

a

C

e

l

b

i

s

s

o

P

m

e

l

b

o

r

P

Unit does not run

Fuse blown or circuit tripped

Replace fuse, reset breaker. If repeats, check

fuse or breaker size. Check for shorts in unit

wiring & components

Power cord not plugged in

Plug it in

System button in “OFF” position

Set correctly

Inoperative system button or open
electronic control board

Test for continuity. Check alarms. Correct
as needed.

Loose or disconnected wiring

control board or other components

Check wiring & connections. Reconnect per

wiring diagram

e

s

u

a

C

e

l

b

i

s

s

o

P

m

e

l

b

o

r

P

Evaporator coil

freezes up

Dirty fi

l

a

u

n

a

M

s

r

e

n

w

O

n

i

d

e

d

n

e

m

m

o

c

e

r

s

a

n

a

e

l

C

r

e

t

l

Restricted airfl ow

Check for dirty or obstructed coil. Use

pressure wash or biodegradable cleaning

agent to clean

Inoperative thermistor Check alarms. Replace as necessary.

Short of refrigerant

De-ice coil & check for leak

Inoperative fan motor

Test fan motor & replace if inoperative

Partially restricted capillary tube

De-ice coil. Replace capillary tube.

e

s

u

a

C

e

l

b

i

s

s

o

P

m

e

l

b

o

r

P

Compressor runs

continually & does

not cycle off

Excessive heat load

Unit undersized. Test cooling performance &

replace with larger unit if needed. See sizing chart.

Restriction in line

Check for partially iced coil & check

temperature split across coil

Refrigerant leak

Find leak and repair.

Compressor relay contacts stuck

Check operation of t-stat. Replace if contacts

remain closed.

Remote wall T-stat incorrectly wired Refer to appropriate wiring diagram

Thermistor shorted

Replace thermistor or electronic control board

e

s

u

a

C

e

l

b

i

s

s

o

P

m

e

l

b

o

r

P

Electronic control

board does not

turn unit off

Compressor relay contacts stuck

Replace electronic control board

Temperature set at coldest point

Turn to higher temp. setting to see if unit

cycles off. If not, replace control board.

Incorrect wiring

Refer to appropriate wiring diagrams

Unit undersized for area to be

cooled

Refer to industry standard sizing chart

Defective thermistor

Replace thermistor or electronic control board

Possible Solution

Possible Solution

Possible Solution