COOLING ONLY ROOM AIR CONDITIONERS: TROUBLESHOOTING TIPS

e

s

u

a

C

e

l

b

i

s

s

o

P

m

e

l

b

o

r

P

Compressor

does not run

Low voltage

Check voltage at compressor. 115V & 230V

units will operate at 10% voltage variance

Temperature not set cold enough or
room air thermistor inoperative

Set temperature to lower than ambient position.

Test thermistor and replace if inoperative.

Compressor hums but cuts off on

overload

Hard start compressor. Direct test compressor.

If compressor starts, add starting components

Open or shorted compressor

windings

Check for continuity & resistance

Open overload

Test overload protector & replace if inoperative

Open capacitor

Test capacitor & replace if inoperative

Inoperative system button

Test for continuity in all positions. Replace if

inoperative switch or electronic board.

Broken, loose or incorrect wiring

Refer to appropriate wiring diagrams to check

wiring. Correct as needed.

e

s

u

a

C

e

l

b

i

s

s

o

P

m

e

l

b

o

r

P

Fan motor

does not run

Inoperative system button

Test button & replace user interface if inoperative

Broken, loose or incorrect wiring

Refer to applicable wiring diagram

Open capacitor

Test capacitor & replace if inoperative

Fan speed button defective Replace user interface if inoperative

Inoperative fan motor

Test fan motor & replace if inoperative (be sure

internal overload has had time to reset)

e

s

u

a

C

e

l

b

i

s

s

o

P

Possible Solution

Possible Solution

Possible Solution

m

e

l

b

o

r

P

Does not cool or

only cools slightly

Undersized unit

Refer to industry standard sizing chart

or shorted

Indoor ambient thermistor open

See alarms and replace thermistor if needed.

Dirty fi

l

a

u

n

a

M

s

r

e

n

w

O

n

i

d

e

d

n

e

m

m

o

c

e

r

s

a

n

a

e

l

C

r

e

t

l

Dirty or restricted condenser or

evaporator coil

Use pressure wash or biodegradable cleaning

agent to clean

Poor air circulation

Adjust discharge louvers. Use high fan speed

Fresh air or exhaust air door open

Close doors. Instruct customer on use of this

feature

Low capacity - undercharge

Check for leak & make repair

Compressor not pumping properly

Check amperage draw against nameplate. If

not conclusive, make pressure test