COOLING ONLY ROOM AIR CONDITIONERS: TROUBLESHOOTING TIPS

Possible Solution

e

s

u

a

C

e

l

b

i

s

s

o

P

m

e

l

b

o

r

P

Compressor runs

for short periods

only. Cycles on

overload

Overload inoperative. Opens too

soon

Check operation of unit. Replace overload if

system operation is satisfactory

Compressor restarted before

system pressures equalized

Control’s default of 3 minutes wait delay timer
inoperative. Replace board.

Low or fl uctuating voltage

Check voltage with unit operating. Check for

other appliances on circuit. Air conditioner

should be in a dedicated circuit for proper

voltage & fused separately

Incorrect wiring

Refer to appropriate wiring diagram

Shorted or incorrect capacitor

Test capacitor and replace if needed.

Restricted or low air flow through

condenser coil or evaporator coil

Check for proper fan speed or blocked

coils. Correct as needed.

Compressor running abnormally
hot

Check for kinked discharge line or restricted

condenser. Refrigerant overcharge. Check
amperage, connections.

e

s

u

a

C

e

l

b

i

s

s

o

P

m

e

l

b

o

r

P

Unit does not

turn on

No power

Check power supply. Check LCDI plug. Check
wire connections. Check if panel is locked.

Incorrect wiring

Refer to appropriate wiring diagram

Defective thermistor

Replace thermistor or electronic control board

e

s

u

a

C

e

l

b

i

s

s

o

P

m

e

l

b

o

r

P

Noisy operation

Poorly installed

Refer to Installation Manual for proper

installation

Fan blade striking chassis

Reposition - adjust motor mount

Compressor vibrating

Check that compressor grommets have not

deteriorated. Check that compressor mounting

parts are not missing

Improperly mounted or loose

cabinet parts refrigerant tubes

Check assembly & parts for looseness,

rubbing & rattling pipes, etc.

e

s

u

a

C

e

l

b

i

s

s

o

P

m

e

l

b

o

r

P

Water leaks into

the room

Evaporator drain pan overfl owing

Clean obstructed drain trough

Condensation forming underneath
base pan

Evaporator drain pan broken or cracked.
Reseal or replace. No chassis gasket installed.
Install chassis gasket

Poor installation resulting in rain

entering the room

Check installation instructions. Reseal as

required

Condensation on discharge grille

louvers

Dirty evaporator coil. Use pressure wash
or biodegradable cleaning agent to clean.
Environmental phenomena: point supply
louvers upward. Put on high fan.

Chassis gasket not installed

Install gasket, per Installation manual

Downward slope of unit is too

steep inward

Refer to installation manual for proper

installation

Possible Solution

Possible Solution

Possible Solution