3. TARGET TRACKING (TT)

3-7

[TT

TARGET

MENU]


1 TT SELECT
MANUAL100/
AUTO 25/
AUTO 50/
AUTO 75/
AUTO 100
4 ALL CANCEL
NO/YES
3 REF TARGET VECTOR
OFF/ON

3.6 Manual

Acquisition

Maximum 100 targets may be acquired manually depending on the acquisition
condition set on the TT TGT menu.

3.6.1

Setting manual acquisition conditions

1. Right-click the arrow in the TT ACQ MODE box at the right side to show the

TT TARGET menu.







TT TARGET menu

2. Select 1 TT SELECT.
3. Select MANUAL 100, AUTO 25, AUTO 50 or AUTO 75 as appropriate. For

details see the table on page 3-5.

4. Push the right button to close the menu.

3.6.2

Manually acquiring targets

By keyboard

1. Put the cursor on the target you want to acquire.
2. Press the [ACQ] key.

By trackball

1. With the cursor inside the effective display area, roll the scrollwheel to show

"TT TARGET DATA & ACQ" in the guidance box.

2. Put the cursor on the target you want to acquire.
3. Push the left button to acquire the target.