54 sub monitor (a, b, c and w types) – Furuno FAR-2107(-BB) User Manual
Page 127
1. RADAR OPERATION
1-105
1.54
Sub Monitor (A, B, C and W types)
The picture from a radar outside the LAN network can be shown on this radar
(processor unit+display unit+control unit).
1. Put the cursor in the ANTENNA box at the upper left side of the screen.
2. Right-click to show the ANT SELECT menu.
[ANT
SELECT]
ANT1:
X-BAND
12
FORE
ANT2:
X-BAND
12
MAIN TOP
ANT3: X-BAND
MAIN TOP
12
ANT4: X-BAND
AFT
OWN RADAR No.: 2
1 DISP1
ANT1
MASTER
2 DISP2
ANT2
MASTER
* Not available on IMO or A radar.
9 STORE INTER-SW
NO/YES
0 SUB MONITOR*
OFF/ON
3 DISP3
ANT3
MASTER
4 DISP4
ANT4
MASTER
12
3. Spin the scrollwheel to select 0 SUB MONITOR then push the left button.
4. Spin the scrollwheel to select ON then push the left button.
The antenna box shows "SUB" and the image from the sub monitor is shown
on this radar
5. Push the right button to close the menu.
Antenna-related functions of the sub monitor; for example, pulselength, cannot
be controlled from this radar.