Furuno FAR-2107(-BB) User Manual
Page 107
1. RADAR OPERATION
1-85
Alarm name
(visual
indication)
Visual alarm, reason
To quit alarm status
AIS ALARM (See section 4.15.)
DUAL RADAR ALARM (Non-IMO only)
EXT RADAR
STBY
External radar is in standby
Set external radar in transmit to erase
indication.
EXT RADAR
ERROR
External radar malfunction
Restore external radar to normal
condition to erase indication.
EXT RADAR
HDG SET
Problem with heading data at
external radar.
Re-set external radar's heading data
to erase indication.
OTHER ALARM
ANCHOR
WATCH
Ship has drifted more than a
threshold value.
Acknowledge indication by pressing
the [ALARM ACK] key or left-clicking
the ALARM ACK box.
ARRIVAL
Own ship has arrived to a
waypoint.
Acknowledge indication by pressing
the [ALARM ACK] key or left-clicking
the ALARM ACK box.
CHECK INT-SW
Interswitch malfunction
Acknowledge indication by pressing
the [ALARM ACK] key or left-clicking
the ALARM ACK box. Check
interswitch.
DEPTH
Depth is lower or higher than
threshold value.
Acknowledge indication by pressing
the [ALARM ACK] key or left-clicking
the ALARM ACK box.
HEADING SET
Heading signal has been
restored.
Press the [ALARM ACK] key to erase
the message. Match the on-screen
HDG readout with the actual compass
reading, if necessary.
MEMORY CARD
FULL
Memory card is full
Acknowledge indication by pressing
the [ALARM ACK] key or left-clicking
the ALARM ACK box.
TARGET ALARM A target has entered (or exited)
the target alarm zone. Target
flashes.
Acknowledge indication by pressing
the [ALARM ACK] key or left-clicking
the ALARM ACK box.
WATCH WATCH
0:00
(WATCH appears and time count
freezes at 0:00).
Press the [ALARM ACK] key or click
the WATCH box with the left button.
The WATCH box is displayed in
normal video and the timer is reset.
XTE
Own ship is off course more than
threshold value.
Acknowledge indication by pressing
the [ALARM ACK] key or left-clicking
the ALARM ACK box.