beautypg.com

FUJITSU MPE3XXXAE User Manual

Page 118

background image

C141-E093-01EN

5 - 53

Table 5.10 Format of insurance failure threshold value data

Byte

Item

00, 01

Data format version number

02

Threshold 1

Attribute ID

03

Insurance failure threshold

04 to 0D

Reserved

0E to 169

Threshold 2 to
threshold 30

(The format of each threshold value is the same as
that of bytes 02 to 0D.)

16A to 17B

Reserved

17C to 1FE

Vendor unique

1FF

Check sum

Data format version number

The data format version number indicates the version number of the data format of the
device attribute values or insurance failure thresholds. The data format version numbers of
the device attribute values and insurance failure thresholds are the same. When a data
format is changed, the data format version numbers are updated.

Attribute ID

The attribute ID is defined as follows:

Attribute ID

Attribute name

0

(Indicates unused attribute data.)

1

Read error rate

2

Throughput performance

3

Spin up time

4

Start/stop count

5

Re-allocated sector count

7

Seek error rate

8

Seek time performance

9

Power-on time

10

Number of retries made to activate the spindle motor

12

Number of power-on-power-off times

13 to 198

(Reserved)

199

Ultra ATA CRC error rate

200

Write error rate

201 to 255

(Unique to vendor)