C141-E093-01EN

5 - 51

If an attribute value is below the insurance failure threshold value, the device is about to fail or
the device is nearing the end of its life . In this case, the host recommends that the user
quickly backs up the data.

At command issuance (I-O registers setting contents)

1F7

H

(CM)

1

0

1

1

0

0

0

0

1F6

H

(DH)

Ч

Ч

Ч

DV

xx

1F5

H

(CH)

1F4

H

(CL)

1F3

H

(SN)

1F2

H

(SC)

1F1

H

(FR)

Key (C2h)

Key (4Fh)

xx
xx

Subcommand

At command completion (I-O registers setting contents)

1F7

H

(ST)

Status information

1F6

H

(DH)

Ч

Ч

Ч

DV

xx

1F5

H

(CH)

1F4

H

(CL)

1F3

H

(SN)

1F2

H

(SC)

1F1

H

(ER)

Key-failure prediction status (C2h-2Ch)
Key-failure prediction status (4Fh-F4h)

xx
xx

Error information

The attribute value information is 512-byte data; the format of this data is shown below. The
host can access this data using the SMART Read Attribute Values subcommand (FR register =
D0h). The insurance failure threshold value data is 512-byte data; the format of this data is
shown below. The host can access this data using the SMART Read Attribute Thresholds
subcommand (FR register = D1h).