Specifications
Electrical
MCC and C series – 220V 60Hz
5.0 full load amps
E series – 230V 50Hz
5.0 full load amps
Power cord provided on icemaker and dispenser.
Plumbing
3/8" OD push-in water inlet
3/4" MPT drain
3/8" FPT condenser inlet (water-cooled condenser only)
3/8" MPT condenser drain (water-cooled condenser only)
Notes: Slope to drain of 1/4" per foot (6mm per 30.4cm run) with a 1/2" minimum is recommended
Water shut-off recommended within 10 feet (3m), drain to be hard piped and insulated
Separate drains for icemaker and condenser. To prevent back flow, do NOT connect drains.
Follett recommends installation of an activated carbon filter in icemaker inlet water line
Ambient
Air temp
38˚ C/100˚ F max.
10˚C/50˚F min. (best performance below 27˚C/80˚F)
Water temp
32˚C/90˚F max.
4˚C/40˚F min. (best performance below 21˚C/70˚F)
Water pressure
5 Bar/70 P.S.I max. (482kPa)
.69 Bar/89kPa/10 P.S.I. min.
Electrical connections
Model
Electrical connection
Circuits required
C25FB400A/W, C50FB400A/W
cord provided
220V 60Hz
E25FB400A/W, E50FB400A/W
230V 50Hz
C25CT400A/W, C50CT400A/W
cord provided
220V 60Hz
E25CT400A/W, E50CT400A/W
230V 50Hz
C25CR400A/W, C50CR400A/W
cord provided
220V 60Hz, (2) circuits required
E25CR400A/W, E50CR400A/W
230V 50Hz, (2) circuits required
MCC400A/W used with CVU155N
icemaker and dispenser:
220V 60Hz, (2) circuits required
hard-wiring: Cord and plug
connection provided for
bin
signal
(2) MCC400A/W used with CVU155N
icemakers and dispenser:
220V 60Hz, (3) circuits required
hard-wiring: Cord and plug
connection provided for
bin
signal