Table 2 – Compressor data
Compressor current draw

Air-cooled
Ambient air temp.

15.6˚C/60˚F

21.1˚C/70˚F

26.7˚C/80˚F

32.2˚C/90˚F

37.8˚C/100˚F

3.2A

3.3A

3.4A

3.5A

3.6A

Water-cooled
Water temp. at float

10˚C/50˚F

15.6˚C/60˚F

21.1˚C/70˚F

26.7˚C/80˚F

32.2˚C/90˚F

3.2A

3.3A

3.4A

3.5A

3.6A

Locked rotor amps 26.3

Table 3 – Gearmotor data

Gearmotor current

1.3A (nominal)

Locked rotor amps

6.8 amps

Table 1 – Refrigeration pressure data

Notes:

1) Water regulating valve is factory set at 225 PSIG head pressure.

2) Readings within 10% of above table values should be considered normal.

Ambient air temperature

°C

Icem

ak

er inlet w

ater temper

ature

°C

°C

10

21

32

16

12/1.6

12/1.6

13.1/1.7

27

16.9/2.1

16.8/2.1

18.3/2.2

38

16.3/2.5

22.5/2.6

23.9/2.8

bar

bar

bar

Ambient air temperature

°F

Icem

ak

er inlet w

ater temper

ature

°F

°F

50

70

90

60

174/23

174/23

190/25

80

245/31

244/30

265/32

100

237/37

326/38

347/40

psi

psi

psi

Air-cooled Icemaker Refrigeration Pressure

Discharge Pressure/Suction Pressure

Ambient air temperature

°C

Icem

ak

er inlet w

ater temper

ature

°C

°C

10

21

32

10

16.3/1.9

16.3/1.9

16.3/1.9

21

16.9/2.0

17.2/2.1

16.9/2.1

38

20.2/2.3

20.2/2.3

20.0/2.3

bar

bar

bar

Ambient air temperature

°F

Icem

ak

er inlet w

ater temper

ature

°F

°F

50

70

90

50

236/28

237/28

236/28

70

235/29

235/30

235/30

90

250/34

250/34

250/34

psi

psi

psi

Water-cooled Icemaker Refrigeration Pressure

Discharge Pressure/Suction Pressure

21

Ambient Air Temperature ˚F/˚C

Inlet W

a

ter

T

emper

ature

˚F/˚C

F

C

50

10

60

16

70

21

80

27

90

32

60

16

510

232

482

219

454

206

424

193

394

179

70

21

454

206

435

198

417

190

385

175

354

161

80

27

397

180

389

177

380

173

347

158

313

142

90

32

335

152

329

150

323

147

297

135

270

123

100

38

273

124

270

123

266

121

247

112

227

103

lbs.

kg.

lbs.

kg.

lbs.

kg.

lbs.

kg.

lbs.

kg.

Air-cooled icemaker capacity/24 hrs.

Ambient Air Temperature ˚F/˚C

Inlet W

ater T

e

m

per

ature ˚F/˚C

F

C

50

10

60

16

70

21

80

27

90

32

60

16

451

204

423

192

394

179

371

168

352

160

70

21

447

202

413

187

390

177

361

163

342

155

80

27

442

200

409

185

380

172

352

160

333

151

90

32

437

199

399

181

371

168

342

155

323

146

100

38

428

194

394

179

361

163

333

151

309

140

lbs.

kg.

lbs.

kg.

lbs.

kg.

lbs.

kg.

lbs.

kg.

Water-cooled icemaker capacity/24 hrs.

Performance with new RG Group 1/2 ton coil
(Note: Data expressed in lbs/hr and kg/hr)

Note: Nominal values – actual production may vary by ± 10%