Diagnostic sequence – Stage 10

If the water level in the float reservoir drops to an unacceptable level, the WTR LED goes out, shutting the
icemaker off. Also, the BT LED comes on, preventing the icemaker from restarting for twenty minutes. If water is
restored, the WTR LED comes back on and flashes to alert the technician that water to icemaker has been lost.
The icemaker restarts at the end of the 20 minute time delay. The flashing WTR LED can be cleared by pressing
the reset button.

RED

WTR

B-E

B-T

2ND

60M

20M

C

POWER

DR

WHITE

BLACK

YELLOW

WHITE

4

3

2

T.O.L.

START

RUN

GEARMOTOR

COMPRESSOR

R

POTENTIAL

START RELAY

RUN

CAP.

CAPACITOR

START

C

S

2

1

5

T.O.L.

L1

L2

COMP

FAN

DRV

BIN

T-STAT

BIN

SIGNAL

SWITCH

WATER
SENSOR

G

GREEN/YELLOW

GRN IN
ELEC BOX

BROWN

BLUE

WHITE

WHITE

BLACK

BLACK

ORANGE

RED

BLACK

BLACK

BLACK

BLACK

VIOLET

VIOLET

WHITE

BLACK

RED

RED

BLUE

BLACK

FAN

M

ORANGE

BLACK

L

N

HIGH PRESSURE
SAFETY SWITCH

COMPRESSOR
SWITCH

DISPENSER