External Trigger Programmable Exposure
• Also known as “Edge Pre-select” exposure. See the timing diagram below.
• The external trigger edge initiates the exposure process. The active external trigger edge can be selected as
either the low-high or high-low transition.
• The delay from active trigger edge to start of exposure is programmable from 1μs to 4 seconds (1μs steps) .
• Exposure duration is programmable from 100μs to 4 seconds (1μs steps).
• Supports
timing for fastest possible frame rates. Start of exposure is aligned
on the next horizontal line while exposure duration granularity is 1µs. Exposure and sensor readout can be
concurrent.
• Supports
" on page 47
timing. Exposure granularity is 1µs. Exposure and sensor readout must be
sequential, limiting the maximal frame rate.
• Any external trigger received before the previous exposure is complete is ignored. An application can elect to
receive messages about ignored triggers. See
.
Programmable Synchronous Mode Exposure Timing