Genie Monochrome Series-GigE Vision Camera

Network Tools 83

• If the camera requires a persistent IP address, select the bullet to assign a persistent IP immediately with

recovery. Enter the new IP address and click on Recover Camera.

Important: Any changes made with this tool will update the Genie flash memory. Do not remove power from the
Genie camera for a minimum 10 seconds.

Sapera GigE Server Details

This section provides additional details on the GigE Server not covered in the Genie installation section of this
manual. Generally the Genie automatic installation requires no user intervention.
• The Sapera GigE Server implements the GigE Vision Control Protocol (GVCP). This provides the interface to

generate GVCP messages to control and configure a GigE Vision device.

• GigE Server handles the heartbeat messages, allowing an application in development, to be single-stepped

while in debug mode, without loss of the camera connection.

• GigE Server is a single application going through the firewall. This simplifies firewall settings as only this

application needs to be listed in the firewall exceptions.

• The GigE Server periodically rescans the network to discover any new camera that might have been added to

the network. This will also identify devices removed.

• When required, it is possible to disabled the GigE server. A Sapera application will then directly be linked to

the library responsible for GigE Vision control channel communications. This can be used to minimize inter-
process communications.

• The GigE Server Status window provides valuable information about the GigE Vision devices present on your

system (see

"

Troubleshooting