Feature type bool, Feature interdependence diagrams – Faber Genie M1600 User Manual
Page 74

72 • Operational Reference
Genie Monochrome Series-GigE Vision Camera
Note 1: not displayed in CamExpert; not saved in a camera configuration file (CCF)
Feature Type BOOL
Feature Name
Access
Type
Value
LUTEnable RW
BOOL
True/False
TriggerEnable RW
BOOL
True/False
TriggerSoftware
RW
BOOL
True/False
FlatFieldEnable
RW
BOOL
True/False
SaveCameraConfiguration
WO BOOL
True/False
LoadCameraConfiguration
WO BOOL
True/False
Feature Interdependence Diagrams
The following diagrams describe operational feature availability which are dependent on user selected modes. These
diagrams show what features are set to a value, and they show which feature parameters remain as user variables.
Each diagram uses the following symbol set to indicate the dependent action type.
Function Enabled
The event “Feature Info Changed” is sent. Other feature properties might have changed too.
Function Disabled
The event “Feature Info Changed” is sent. Other feature properties might have changed too.
Forced Value
The event “Feature Value Changed” is sent if the forced value is different from the previous value.
Set Max Value
The event “Feature Info Changed” is sent if the new value is different than the previous value.
gray box
User Action
Set Max Value
The event “Feature Value Changed” is sent if the new range causes the value to be not within the
valid range. The feature is usually set to the new maximum. When the maximum range increases,
the “Feature Value Changed” event is never set.