Voltage Dips and Swells

If the voltage passes the upper limit (V

N

+ 10%) or lower limit (V

N

– 10%), the

event is registered as a voltage swell or dip, respectively (thresholds are
adjustable in PQ Log).

The duration, time, and extreme value of the dip or swell is also recorded.

Zeit

Time

90% Un

Duration

Depth

Heigth

Duration

100% Un

110% Un

egb019.eps

Figure 16. Voltage Dips and Swells

Voltage Harmonics

Voltage harmonics are defined as voltage components that have a frequency
that is an integer multiple of the fundamental frequency of the line power
voltage. Logging function A records each individual voltage harmonic, up to
the 50

th

order. These values are averaged over the interval length defined in

PQ Log.