3 manual sounder operation, 7 4.2.3 how to enable automatic sounder operation, 1 selecting the manual mode – Furuno NAVNET 1724C User Manual
Page 136: 2 selecting display range
4. VIDEO SOUNDER OPERATION
4-7
4.2.3 How to enable automatic sounder operation
1. If not displayed, press the HIDE/SHOW key to show the sounder soft keys.
2. Press the AUTO/D. BOX soft key.
AUTO MODE
▲
¤
CRUISING
¡
FISHING
¡
OFF (MANUAL)
▼
Mode/frequency window
3. Use the Cursor pad or the ENTER knob to select CRUISING or FISHING as
appropriate.
4. Press the RETURN soft key.
4.3 Manual Sounder Operation
Manual operation is useful for observing fish schools and bottom using a fixed gain setting.
The gain, range and range shift functions used together give you the means to select the
depth you can see on the screen. The basic range can be thought of as providing a
“window” into the water column and range shifting as moving the “window” to the desired
depth.
4.3.1 Selecting the manual mode
1. If not displayed, press the HIDE/SHOW key to show the sounder soft keys.
2. Press the AUTO/D. BOX soft key to show the mode/frequency window.
3. Select OFF (MANUAL).
4. Press the RETURN soft key.
4.3.2 Selecting
display
range
Press the [RANGE +] or [RANGE -] key to select a range. The default ranges in feet, meters,
fathoms and passi/braza are as below. Note that the range cannot be changed in the
automatic sounder mode.
Default sounder ranges
Range 8
Range 1
Range 2
Range 3
Range 4
Range 5
Range 6
Range 7
ETR-6/10N ETR-30N
15 ft
30 ft
60 ft
120 ft
200 ft
400 ft
1000 ft
4000 ft
4500 ft
5 m
10 m
20 m
40 m
80 m
150 m
300 m
1200 m
1500 m
3 fa
5 fa
10 fa
20 fa
40 fa
80 fa
150 fa
650 fa
900 fa
3 P/B
5 P/B
10 P/B
30 P/B
50 P/B
100 P/B
200 P/B
700 P/B
900 P/B