7 external equipment setup (option), Speed source – Furuno GP-1850DF User Manual
Page 33
![background image](/manuals/102229/33/background.png)
3-7
3.7 External Equipment Setup (Option)
This section shows you how to set up the GP-1850F/1850DF when external equip-
ment is connected. If a water temperature/speed sensor is installed, you should
complete this section with the boat in the water and running, to confirm speed/
water temperature readout.
Speed Source
1. Press the [MENU] key.
2. Press the software key labeled "DISPLAY OPTIONS".
3. Press the software key labeled "NEXT PAGE" to display the following display.
RETURN
EDIT
DISPLAY
SETUP2
s
SPEED SOURCE
GPS
TEMP SOURCE
OWN XDCR
TEMP GRAPH
OFF
ZOOM MARKER
OFF
SPEED ADJ.
+00%
TEMP ADJ.
+00.0
°
F
DEPTH ADJ.
+0.0ft
SPD
12.3kt
TEMP
62.5
°
F
DEPTH
2000.0ft
DGPS 3D
Figure 3-10 Display Setup 2 Display
4. Select "SPEED SOURCE" by the arrow key.
5. Press the software key "EDIT" to display the following message.
SPEED SOURCE
▲
OWN PDDWHL
GPS
▼
Figure 3-11 Speed Source Display
6. Select source of speed by the arrow key; "OWN PDDWHL" (speed sensor) or
"GPS".
Adjust speed when you select "OWN PDDWHL". Refer to next page.
7. Press the software key labeled "ENTER".
8. Press the [PLOT] key to finish.