beautypg.com

3 uais transponder – Furuno FA-150 User Manual

Page 16

background image

10

1.3 UAIS

Transponder

Mount the transponder, where it is protected from rain and water splash.

This unit can be installed on a bulkhead. Install it, referring to the outline drawing.

When selecting a mounting location for the transponder, keep the following in mind:

Keep the transponder out of direct sunlight.

The temperature and humidity should be moderate and stable.

(Operating temperature range: -15°C to +55°C)

Locate the unit away from exhaust pipes and vents.

The mounting location should be well ventilated.

Mount the unit where shock and vibration are minimal.

Keep the unit away from electromagnetic field generating equipment such as

motor, generator.

For maintenance and checking purposes, leave sufficient space at the sides and

rear of the unit and leave slack in cables. Refer to the outline drawing.

A magnetic compass will be affected if the unit is placed too close to it. Observe

the following compass safe distances to prevent disturbance to the magnetic

compass:

Standard compass: 1.2 meters

Steering compass: 0.8 meters


Mounting

Fix the unit with four self-tapping screws.

POWER

385

420

7

180

1

250

R3.5

405

1

7.5

180

1

2-

7

 Fixing holes

100