beautypg.com

5 connection of rci, Rci connection. refer to, Section 1.3.5, "connection of rci – FUJITSU C120-E361-04EN User Manual

Page 28

background image

1-10

C120-E361-04EN

CHAPTER 1 RCI Build Procedure

7

Execute the setrci -c addconfig command on main unit B to expand the RCI

configuration.

8

Display the RCI status by executing the setrci -c statcommand on main unit A.

9

Verify that the added main unit is incorporated.

1.3.5

Connection of RCI

According to the following procedure, connect different units with RCI cables by

using a daisy-chain connection.

1

Prepare RCI branching connectors and RCI terminating resistors.

All of them are supplied with the main unit.

2

Connect the main unit and I/O units with RCI cables (see

Figure 1.9

and

Figure 1.10

.)

1

Connect the RCI branching connector (1) to the RCIport on an XSCF unit of the
main unit.

2

Connect the RCI branching connector and the RCI port of an I/O unit with an RCI

cable (2) by using a daisy-chain connection.

XSCF> setrci -c set 2

The command completed successfully

XSCF> setrci -c addconfig

The command completed successfully

XSCF> setrci -c stat

HOST

address 000102ff

Active

LIST

address pwr alm I/F sys-phase ctgry dev-cls sub-cls tm-out

000101ff OFF - ACT -- host 0001 0b -

000102ff OFF - ACT -- host 0001 0b -

003001ff OFF - ACT -- disk 0400 04 -

003002ff OFF - ACT -- disk 0400 04 -

The command completed successfully