CHAPTER 1 RCI Build Procedure

1.3.2

New setup of two RCI Hosts

Figure 1.6 New setup of two RCI Hosts

1

Log in to the XSCF Shell.

2

On main unit A, execute the setrci -c stat command to display the RCI status.

3

Verify that the RCI address is 000f7fff.

Remarks: 000f7fff is the default value of the RCI address. If the default value is not

set, execute the setrci -c init command to initialize the value.

If the system is powered off, you can use the setrci -c init command.

4

In a similar manner, display the RCI status of main unit B to verify that the RCI

address is 000f7fff.

5

Connect the main unit and I/O units with RCI cables (see

Figure 1.6

).

Connect an RCI branching connector to each of the RCI ports, and connect them with

RCI cables by using a daisy-chain connection.

Connect an RCI terminating resistor to the branching connector at either end of the

RCI connection. Refer to

Section 1.3.5, "Connection of RCI."

6

Turn on the AC input to all the RCI device which are in the RCI connection.

XSCF> setrci -c stat

HOST

address 000f7fff

Inactive

The command completed successfully

XSCF> setrci -c init

The command completed successfully

RCI I/O unit

RCI I/O unit

RCI

Host A

RCI

Host B