beautypg.com

4 mounting, 1 checks before mounting the drive – FUJITSU MCP3130SS User Manual

Page 78

background image

Installation

4-12 C156-E228-02EN

4.4 Mounting

4.4.1 Checks before mounting the drive

Before mounting the optical disk drive in the system cabinet, check whether the
setting switches and terminals are set correctly.

Table 4.8 shows the checklist.

Table 4.8 Setting checklist

Setting

item

Setting

on:

Default

Check

1 SCSI

ID

SW1-01
SW1-02
SW1-03

OFF
OFF
OFF

(SCSI ID= )

o

OFF

o

ON

o

OFF

o

ON

o

OFF

o

ON

2 SCSI data bus parity check

SW1-04

ON

o

OFF

o

ON

3 Write

cache

mode

SW1-05 OFF

o

OFF

o

ON

4 Device

type

mode

SW1-06 ON

o

OFF

o

ON

5 Spindle automatic stop mode

SW1-07

ON

o

OFF

o

ON

S

ett

ing sw

it

ch

6 Factory

test

mode

(user setting inhibited)

SW1-08 OFF

o

OFF

o

ON

Setting

item

Setting

on:

Default

Check

1 Supplied from both ODD and

TERMPWR pin.

CNH1 1-2
CNH1 3-4

Short
Short

o

Short

o

Open

o

Short

o

Open

2 Supplied from ODD

CNH1 1-2
CNH1 3-4

Short
Short

o

Short

o

Open

o

Short

o

Open

CNH1

3 Supplied from TERMPWR pin.

CNH1 1-2
CNH1 3-4

Short
Short

o

Short

o

Open

o

Short

o

Open

Check

item

Check

1 Drive location on SCSI bus

o

Other

o

Either

than end end

Term

ina

ti

ng

res

ist

or

2 SCSI terminating resistor mode (CNH1 5-6)

o

Open

o

Short

This manual is related to the following products: