4 mounting, 1 checks before mounting the drive – FUJITSU MCP3130SS User Manual
Page 78

Installation
4-12 C156-E228-02EN
4.4 Mounting
4.4.1 Checks before mounting the drive
Before mounting the optical disk drive in the system cabinet, check whether the
setting switches and terminals are set correctly.
Table 4.8 shows the checklist.
Table 4.8 Setting checklist
Setting
item
Setting
on:
Default
Check
1 SCSI
ID
SW1-01
SW1-02
SW1-03
OFF
OFF
OFF
(SCSI ID= )
o
OFF
o
ON
o
OFF
o
ON
o
OFF
o
ON
2 SCSI data bus parity check
SW1-04
ON
o
OFF
o
ON
3 Write
cache
mode
SW1-05 OFF
o
OFF
o
ON
4 Device
type
mode
SW1-06 ON
o
OFF
o
ON
5 Spindle automatic stop mode
SW1-07
ON
o
OFF
o
ON
S
ett
ing sw
it
ch
6 Factory
test
mode
(user setting inhibited)
SW1-08 OFF
o
OFF
o
ON
Setting
item
Setting
on:
Default
Check
1 Supplied from both ODD and
TERMPWR pin.
CNH1 1-2
CNH1 3-4
Short
Short
o
Short
o
Open
o
Short
o
Open
2 Supplied from ODD
CNH1 1-2
CNH1 3-4
Short
Short
o
Short
o
Open
o
Short
o
Open
CNH1
3 Supplied from TERMPWR pin.
CNH1 1-2
CNH1 3-4
Short
Short
o
Short
o
Open
o
Short
o
Open
Check
item
Check
1 Drive location on SCSI bus
o
Other
o
Either
than end end
Term
ina
ti
ng
res
ist
or
2 SCSI terminating resistor mode (CNH1 5-6)
o
Open
o
Short