Specifications

2-4 C156-E228-02EN

2.1.3 Environmental and power requirements

Table 2.3 lists the environmental and power requirements.

Table 2.3 Environmental and power requirements (1 of 2)

Item Specification

Power
requirements

Average

+5 VDC±5% (*1), 1.2A (2.7A max)
Ripple requirement 100mV pp (DC-1 MHz)

Power

Ready

3.9 W (typ) (*2)

consumption

Random seek, read or write

6.1 W (typ) (*2)

(Average) Power

save

mode

Pre-idle mode
Idle mode
Standby mode
Sleep mode

3.9 W (typ) (*2)
2.0 W (typ) (*2)
1.2 W (typ) (*2)
1.2 W (typ) (*2)

Outer
dimensions

With panel

101.6

Ч

150.0

Ч

25.4 mm

(W

×

D

×

H)

Without panel

101.6

Ч

148.4

Ч

25.4 mm

Weight

410 g (with panel)

Environmental
requirements

Operating

Temperature: 5 to 45°C (gradient 15°C /h or less)

(*3)

Relative humidity: 10 to 85% (No condensation)

Maximum wet bulb temperature: 29°C or lower

Idle

Temperature: 0 to 50°C

Relative humidity: 10 to 85% (No condensation)

Maximum wet bulb temperature: 36°C or lower

Transport

Temperature: –40 to 60°C (24 hours or less)

Temperature: –20 to 60°C (24 hours or more)

Relative humidity: 5 to 90% (No condensation)

Maximum wet bulb temperature: 41°C or lower

Installation

Tilt angle

–5° to +10° (*3)