Installation
4-8 C156-E228-02EN
(1) SCSI ID
Table 4.1 shows the SCSI ID settings of the drive.
Table 4.1 SCSI ID setting (SW1)
SCSI ID
SW1-01
SW1-02
SW1-03
0 (*1)
OFF
OFF
OFF
1 OFF
OFF
ON
2 OFF
ON
OFF
3 OFF
ON ON
4 ON
OFF
OFF
5 ON
OFF
ON
6 ON
ON
OFF
7 ON
ON
ON
*1
Setting when shipped
1) Each SCSI device connected to the same SCSI bus must have a
unique SCSI ID.
2) If contention occurs in the ARBITRATION phase, the priority
of the SCSI use authority depends on SCSI IDs as follows:
7 > 6 > 5 > 4 > 3 > 2 > 1 > 0
(2) SCSI data bus parity checking
Table 4.2 shows the settings which determine whether to check the SCSI bus
parity bit. Regardless of the settings, the parity bit is ensured for data transmitted
by the drive.
Table 4.2 SCSI data bus parity checking (SW1)
SCSI data bus parity checking by drive
SW1-04
Checked ON
(*1)
Not checked
OFF
*1
Setting when shipped