beautypg.com

FUJITSU MCP3130SS User Manual

Page 119

background image

7.5 Timing Rule

C156-E228-02EN 7-17

Table 7.7 Timing specifications (3 of 3)

No. Name

Standard

Timing

specification

17

Transfer Period

50 ns

In synchronous data transfer mode, the minimum time
(minimum repetition time) from the leading edge of an
REQ signal to the leading edge of the next REQ signal
or from the leading edge of an ACK signal to the
leading edge of the next ACK signal. The actual value
is defined using a SYNCHRONOUS DATA
TRANSFER REQUEST message exchanged between
the INIT and TARG.

Table 7.8 SCSI BUS Timing specifications

Synchronous data transfer mode

No. Name

Fast-20 Fast-SCSI SCSI-1

Asynchronous

data transfer

mode

1 Arbitration

Delay

2.4

µ

s 2.4

µ

s 2.4

µ

s 2.4

µ

s

2

Bus

Clear

Delay

800ns 800ns 800ns 800ns

3

Bus Free Delay

800ns

800ns

800ns

800ns

4

Bus

Settle

Delay

400ns 400ns 400ns 400ns

5

Cable Skew Delay

3ns

4ns

4ns

4ns

6

Data Release Delay

400ns

400ns

400ns

400ns

7

Receive

Assertion

Period

11ns 22ns 70ns

––

8

Receive Hold Time

11.5ns

25ns

25ns

––

9

Receive

Negation

Period

11ns 22ns 70ns

––

10

Receive Setup Time

6.5ns

15ns

15ns

––

11

Reset

Hold

Time

25ns 25ns 25ns 25ns

12

Selection Abort Time

200ns

200ns

200ns

200ns

13

Selection

Time-out

Delay

250ns 250ns 250ns 250ns

14

System

Deskew

Delay

15ns 20ns 45ns 45ns

15 Transfer

Period

during

Synchronous Data Transfer Phases

50ns 100ns 200ns

––

16

Transmit Assertion Period

15ns

30ns

80ns

––

17 Transmit

Hold

Time

16.5ns

33ns

53ns

––

18

Transmit Negation Period

15ns

30ns

80ns

––

19

Transmit Setup Time

11.5ns

23ns

23ns

––

This manual is related to the following products: