beautypg.com

2 acquiring and tracking targets (arp) – Furuno NATVET 1824C User Manual

Page 56

background image

2. RADAR OPERATION

2-27

2.26.1 Activating/deactivating ARP, TTM

1. Press the

MENU key followed by the ARP SETUP soft key to show the ARP SETUP

menu.

EDIT

RETURN

ARP
SETUP

ARP TARGET INFO

INTERNAL ARP

CANCEL ALL TARGETS

NO

ARP VECTOR MODE

TRUE

ARP VECTOR TIME

30 minutes

HISTORY INTERVAL

OFF

CPA

OFF

TCPA

30 seconds

AUTO ACQUISITION AREA OFF

TARGET ID NUMBER

OFF

ARP setup menu

2. Select ARP TARGET INFO, then press the EDIT soft key to show the ARP TARGET

INFO window.

ARP TARGET INFO

{

{

~

INTERNAL ARP
EXTERNAL ARP
OFF

ARP TARGET INFO window

3. Select INTERNAL ARP, EXTERNAL ARP or OFF as appropriate.

INTERNAL ARP: The radar source must be an ARP-equipped Model 18x4/19x4 series

NavNet radar. Select this item also for a NavNet unit being fed ARP targets.
EXTERNAL ARP: Receive TTM data sentence via NMEA or NETWORK port. Target

tracks are shown but targets cannot be acquired.

OFF: Turns off the ARP or TTM display.

4. Press the ENTER soft key.

5. Press the

MENU key to close the menu.

2.26.2 Acquiring and tracking targets (ARP)

Ten targets may be acquired and tracked manually and automatically. When you attempt to

acquire an 11th target, the message “ARP FULL – ALREADY TRACKING 10 TARGETS!”

appears for five seconds. To acquire another target, terminate tracking of an unnecessary

target as shown in the paragraph “2.26.4 Terminating tracking of ARP targets.”

Manual acquisition
When the automatic acquisition (AUTO ACQ. AREA) is set to on, up to five targets may be

acquired manually. If you attempt to acquire a sixth target, the alert message appears.

1. If not already shown, press the

HIDE/SHOW key to show the radar soft keys.