Mechanical, Environmental – Fluke 434 User Manual
Page 117

Specifications
Mechanical
21
21-15
Mechanical
Item
Customer Specification
Additional Information
Height x Width x Depth
256 x 169 x 64 mm
10.1 x 6.6 x 2.5 inch
Weight
2.1 kg (4.7 lbs)
Including battery pack excluding
current clamps or test leads
Environmental
Item
Customer Specification
Additional Information
Temperature
Operating within specifications
Operating with reduced
specifications
Non Operating (Storage)
+15
°C ... +35 °C
0
°C ... +50 °C
0
°C ... +40 °C
-20
°C ... +60 °C
battery operation only
with power adapter connected
Maximum Relative Humidity
Non Operating (Storage):
Operating:
0 ... 10
°C
10 ... 30
°C
30 ... 40
°C
40 ... 50
°C
No precipitation (non cond.)
No precipitation (non cond.)
95 %
± 5 %
75 %
± 5 %
45 %
± 5 %
Recovery time two hours
No precipitation (no condensing)
battery operation only
Maximum Altitude
Operating
Non Operating
3000 m (10 000 feet)
12 km (40 000 feet)
Above 2000 m derated
overvoltage category
1000V/CATII, 600V/CATIII,
300V/CATIV
Vibration:
Random
Sinusoidal
0.03 g
2
/Hz
3 g
Operating, maximum limits.
MIL-PRF-28800F, class 2,
3.8.4.1&4.5.5.3.1
MIL-PRF-28800F, class 2,
3.8.4.2&4.5.5.3.2
Shock, functional
max 30 g
MIL-PRF-28800F, class 2,
3.8.5.1&4.5.5.4.1
Bench handling (operating)
yes
MIL-PRF-28800F, class 2,
3.8.5.3&4.5.5.4.3
Transit drop
1 meter, see Fluke SOP 39.1,
dated Sept. 22, 1992
Drip proof, Dust resistance
IP 51
IEC60529 (2001-02)