Contents of the setup mode, Contents of the setup mode -2 – FUJITSU fi-4750C User Manual
Page 71
7-2
Contents of the Setup Mode
This section describes the contents of the setup mode.
N
o
Item
Description
Selectable
parameters
Default
1
Double feed check
Specifies the double feed detection. Double
feed is detected by checking the document
length and/or paper thickness.**
No/Yes
No
2
Length check
=No/10/15/20 mm
Specifies the document length to enable
double feed detection sets the document
length.
Tolerance:
No/10/15/20mm
No
3
IPC pre-setting
Scanner automatically sets the
recommended reading parameters. 3 sets
of parameters are available when IPC-4D is
not installed.
Document:
No
1: Sharpen
2: Darken Character
3: Copy Quality
No
4
Resetting of
abrasion counter
Resets the abrasion counter.
---
---
5
Pick start time
setting
Specifies the time from document Insertion
to the start of picking. User can select the
most comfortable Pick start time for the job.
Time:
0.2 to 29.8 sec
1.0 sec
6
Time-out limit setting
Specifies the time the scanner waits for the
next document insertion after the last
document was scanned.
Time:
27 values from
1 to 1999 sec
30 sec
7
ADF front offset
setting*
Specifies the horizontal and vertical offset
of the front side image when using the ADF.
Offset:
H:-2 to +3 mm
V:-2 to +3 mm
Offset:
H: 0 mm
V: 0 mm
8
ADF back offset
setting*
Specifies the horizontal and vertical offset
of the back side image when using the
ADF.
Offset:
H:-2 to +3 mm
V:-2 to +3 mm
Offset:
H: 0 mm
V: 0 mm
9
Flatbed offset
setting*
Horizontal and vertical offset of the FB
image is specified.
Offset:
H:-2 to +3 mm
V:-2 to +3 mm
Offset:
H: 0 mm
V: 0 mm
10
IPC status display
Displays whether or not the image
processing board (IPC-4D) is installed.
---
---
11 SCSI ID setting
The SCSI ID is selectable. Note that the
new setting is made valid after power is
turned off and on again.
SCSI ID:
0/1/2/3/4/5/6/7
5
12
SCSI terminator
setting
Switches the SCSI terminator On/Off.
On/Off
On
13
Low Power Mode
setting
Changes the default setting of the duration
for power save.
5 min.
to 60 min.
15 min.