20

Action

Set the scanner URL as a trusted site for Internet
Explorer.

1. In Internet Explorer, select the [Tools] menu J [Internet

Options].

2. On the [Security] tab, select [Trusted sites] and press

the [Sites] button.

3. Enter the URL of the scanner in the [Add this website to

the zone] field, and press the [Add] button.

Action

When connecting using the scanner name, the
connection will be an intranet connection. When
connecting using an IP address, it will be an internet
connection.
Try the following settings for the corresponding zone.

1. In Internet Explorer, select the [Tools] menu J [Internet

Options].

2. Enable [Active scripting] in either of the following ways:

- On the [Security] tab, click the [Default level] button

to set [Security level for this zone] to [Medium].

- On the [Security] tab, click the [Custom level]

button to set to [Enable] for [Active scripting] under
[Scripting] in the [Settings] area.

3. If connecting via the Internet zone, on the [Privacy] tab,

set the level to [Medium High] or below.

4. Delete all temporary internet files with either of the

following methods.

- For Internet Explorer 6.0

On the [General] tab, click the [Delete Files] button
for [Temporary Internet files].

- For Internet Explorer 7.0

On the [General] tab, click the [Delete] button for
[Browsing history], and click the [Delete files]
button for [Temporary Internet Files].

- For Internet Explorer 8.0

On the [General] tab, click the [Delete] button for
[Browsing history], select the [Temporary Internet
files] check box, and click the [Delete] button.

Action

Press the power button to start the scanner.

Action

Set the proxy server not to be used.

1. In Internet Explorer, select the [Tools] menu J [Internet

Options].

2. Press the [LAN settings] button on the [Connections]

tab.

3. Clear the [Use a proxy server for your LAN (These

settings will not apply to dial-up or VPN connections)]
check box.

Action

Check if SSL is enabled on the [Admin Connection]
window.
The [Admin Connection] window can be displayed as
follows:

1. Select [Network Settings] J [Network Admin] J [Admin

Connection].

Action

Check the specified port number on the [Admin
Connection] window.
The [Admin Connection] window can be displayed as
follows:

1. Select [Network Settings] J [Network Admin] J [Admin

Connection].

Action

1. In Internet Explorer, select the [Tools] menu J [Internet

Options].

2. On the [Advanced] tab, select the [Use SSL 3.0] check

box under [Security] in the [Settings] area.

The URL of the target scanner is not
registered as a trusted site.

In Internet Explorer, the security level for
the target zone is set to [High] on the
[Security] tab in the [Tools] menu -
[Internet Options].
In the case of a custom level, [Prompt]
or [Disable] is set for [Active scripting]
under [Scripting] in the [Settings] area.

The scanner is in standby mode.

A proxy server is being used.

There is an error with the connection
protocol setting.

There is an error with the port number
setting.

In Internet Explorer, [Tools] menu -
[Internet Options] - [Advanced] tab, the
[Use SSL 3.0] check box under
[Security] in the [Settings] area is not
selected.