Kramer electronics ltd – Kramer 4x4 Audio and Dante Mixer User Manual
Page 39

Kramer Electronics Ltd.
FC-404NETxl
– Protocol 3000
37
Function
Description
Syntax
Parameters/Attributes
Example
FEATURE-
LIST?
Get feature state
according to the feature
ID.
COMMAND
#FEATURE-LIST?
feature_id
FEEDBACK
~nn@FEATURE-LIST
feature_id
,
ir_state
feature_id
– Feature ID)
1
– Maestro
2
– Room controller
3
– Maestro panel
ir_state
– IR interface
0
– disable
1
– enable
Get the room controller
feature state (for the room
controller 1):
#FEATURE-LIST?
1
FILE-
HANDLED
For internal use only.
FW
-
TYPE
?
Get the current FW
type status.
Used by Kramer
Network and KUpload
to identify recovery
process.
COMMAND
#FW-TYPE?
FEEDBACK
~nn@FEATURE-LIST
fw_type
Fw_type
–
0
– Application
1
– Safe mode (kboot)
Get the current FW type
status:
#FW-TYPE?
HELP
Get command list or
help for specific
command.
COMMAND
#HELP
#HELP
cmd_name
FEEDBACK
1. Multi-line:
~nn@Device
cmd_name
,
cmd_name…
To get help for command use: HELP (COMMAND_NAME)
~nn@HELP
cmd_name:
description
USAGE:usage
cmd_name
– Name of a specific
command
Get the command list:
#HELP
To get help for
AV-SW-TIMEOUT:
HELP
av-sw-timeout
R> LOGIN (internal) Set protocol The permission system works only if LOGIN allows the user When set, login must It is not mandatory to In each device, some Connection may logout COMMAND #LOGIN login_level , password FEEDBACK ~nn@LOGIN login_level , password ok or ~nn@LOGIN err 004 (if bad password entered) login_level – Level of permissions required (User or password – Predefined password (by PASS command). Default Set the protocol permission #LOGIN admin , 33333 > LOGIN? (internal) Get current protocol The permission system works only if For devices that In each device, some Connection may logout COMMAND #LOGIN? FEEDBACK ~nn@LOGIN login_level login_level – Level of permissions required (User or Get current protocol #LOGIN? LOGOUT (internal Cancel current Logs out from End User or Administrator COMMAND #LOGOUT FEEDBACK ~nn@LOGOUT ok #LOGOUT
permission.
security is enabled with
the “SECUR”
command.
to run commands with
an End User or
Administrator
permission level.
When the permission
system is enabled,
LOGIN enables running
commands with the
User or Administrator
permission level
be performed upon
each connection
enable the permission
system in order to use
the device
connections allow
logging in to different
levels. Some do not
work with security at all.
after timeout.
Admin)
password is an empty string
level to Admin (when the
password defined in the
PASS command is 33333):
permission level.
security is enabled with
the “SECUR”
command.
support security,
LOGIN allows the user
to run commands with
an End User or
Administrator
permission level.
connections allow
logging in to different
levels. Some do not
work with security at all.
after timeout.
Admin)
permission level:
)
permission level.
permission levels to Not
Secure.