Chapter 4 Preparations — Turning power on/off

Turning power on/off

Turning power on

1

Set the switches of the Main Frame AV‑HS60U1/AV‑HS60U2 and the Control Panel AV‑HS60C1/AV‑HS60C2/AV‑HS60C4

to .

f

For the redundant power supply model (AV-HS60U2, AV-HS60C2, AV-HS60C4), set both switches of the power supply 1 and the power
supply 2 to .

f

The power indicator will light up when power is supplied.

Notification when the power is turned on for the first time

When using the products for the first time, connect the Control Panel AV‑HS60C1/AV‑HS60C2/AV‑HS60C4 to the terminal of the Main Frame

AV-HS60U1/AV-HS60U2, and then turn on the power.

Depending on the combination of the purchased Main Frame and the Control Panel, the version of the firmware for each may not match.
When the version of the firmware for the Main Frame and the Control Panel does not match, the Control Panel will not correctly boot when the power is

turned on.

Boot status when the versions do not match

Two buttons out of PST/B bus crosspoint buttons in the ME line in front will blink. One button will blink in green, and the other will blink in red. (Fig. 1)

BUS

SHFT

Green

Red

Fig. 1

f

When it goes into this status, it is necessary to match the firmware version of the Control Panel to the Main Frame.

f

If it does not go into this status and the Control Panel boots normally, the firmware versions of the Main Frame and the Control Panel do match.

f

Check the latest software information and perform the version update of the software if necessary. For details, refer to “To perform the version update
of the software” (page 34).

r

To match the firmware version of the Control Panel to the Main Frame

The firmware of the Control Panel is updated when the following operation is performed. Once the update is correctly performed, the firmware version of
the Control Panel will match with the firmware version of the Main Frame, and it will boot in normal status.

RECALL

STORE

DEL

CHR

LIN

FULL

FULL

WIPE

01s00f

MIX

01s00f

MIX

01s00f

MIX

CG5V

CG6V

CAM1

CAM2

01s00f

MIX

ME2

01s00f

BUS

SHFT

4-1

4-3

4-2

4-4

4-6

4-5

4-7

4-9

4-8

OP

STILL1

BUS

SHFT

4

SDI

IN3

3

SDI

IN2

2

SDI

IN1

1

Black

12

11

10

SDI

IN9

9

SDI

IN8

SDI

IN11

SDI

IN10

8

SDI

IN7

7

SDI

IN6

6

SDI

IN5

5

SDI

IN4

Red

Red

Blue

Fig. 2

Fig. 3

1

Press the button blinking in red (Fig. 1).

Update of the firmware is started.

f

Status when the firmware of the Control Panel is being updated (Fig. 2)

- Eight buttons out of the PGM/A bus crosspoint buttons in the ME line in front will repeatedly blink in blue from left to right.
- Eight buttons out of the PST/B bus crosspoint buttons in the ME line in front will blink in red sequentially from left to right.

Update of the firmware will complete after approximately two minutes.

f

Status when the update of the firmware of the Control Panel is completed

- Eight buttons out of the PST/B bus crosspoint buttons in the ME in front will continue to blink in red. (Fig. 3)
-

Depending on the version of the firmware of the Main Frame, the Control Panel may automatically reboot. The firmware of the Control Panel is

updated correctly for this too.

2

Turn off the power of the Main Frame and the Control Panel.

f

Turn off the power after completing the update of the firmware of the Control Panel.

f

Do not turn off the power of the Main Frame and the Control Panel while the firmware of the Control Panel is still updating (Fig. 2).

3

Turn on the power of the Main Frame and the Control Panel.

Control Panel is booted and the menu screen is displayed in the menu panel when the firmware is correctly updated.