Fuser replacement – iSys iTerra Elite II Color LED Plotter User Manual
Page 41

June 2011: Revision 002
41
 
 
STEP 5
STEP 6
Lower the new belt unit into place, with the lifting bar 
at the front and the drive gear towards the rear of the 
printer. Locate the drive gear into the gear inside the 
printer by the rear left corner of the unit, and lower 
the belt unit flat inside the printer. 
Turn the two fasteners (a) 90˚ to the right until they 
lock. This will secure the belt unit into place. Replace 
the four image drums, complete with their toner 
cartridges, into the printer in the same sequence as 
they came out. 
Close the top cover and press down firmly at both sides 
so that the cover latches closed. 
Fuser Replacement
The fuser is located inside the printer just behind the four image drum units.
 
 
 
STEP 1
STEP 2
Press the
cover release and open the printer’s top cover
fully.
Identify the fuser handle (a). Pull the two fuser retaining 
levers (b) towards the front of the printer so that they are 
fully upright. Remove the new fuser from its packaging and 
remove the transit material 
WARNING! If the printer has recently been powered on, some fuser components will be very hot. 
Handle the fuser with extreme care, holding it only by its handle, which will only be mildly warm to 
touch. A warning label clearly indicates the area. If in doubt, switch the printer off and wait at least 10 
minutes for the fuser to cool before opening the printer cover. 