Diagnosing transceiver modules – H3C Technologies H3C S9500E Series Switches User Manual
Page 75
65
Ordering Name : SFP-GE-SX-MM850
Table 20 Command output
Field Description
Connector Type
Type of the connectors of the transceiver module:
•
SC—Fiber connector, developed by NTT
•
LC—1.25 mm/RJ-45 optical connector developed by Lucent
•
RJ-45
•
CX 4
Wavelength(nm)
•
Fiber transceiver: Central wavelength (in nm) of the laser sent. If the transceiver
module supports multiple wavelengths, every two wavelength values are
separated by a comma.
•
Copper cable: Displayed as N/A.
Transfer distance(xx)
Transfer distance, where "xx" represents the distance unit: km (kilometers) for
single-mode transceiver modules and m (meters) for other transceiver modules.
If the transceiver module supports multiple transfer medium, every two values of
the transfer distance are separated by a comma. The transfer medium is included
in the bracket following the transfer distance value. The following are the transfer
media:
•
9 um—9/125 μm single-mode optical fiber.
•
50 um—50/125 μm multi-mode optical fiber.
•
62.5 um—62.5/125 μm multi-mode optical fiber.
•
TP—Twisted pair.
•
CX4—CX4 cable.
Digital Diagnostic
Monitoring
Support for the digital diagnosis function:
•
YES—Supported.
•
NO—Not supported.
Ordering Name
Product code.
# Display part of the electrical label information about the transceiver modules in interface
GigabitEthernet 3/0/19.
GigabitEthernet3/0/19 transceiver manufacture information:
Manu. Serial Number : XXXXXXXXXXXXXXXXXX
Manufacturing Date : 2008-09-01
Vendor Name : H3C
Table 21 Command output
Field Description
Manu. Serial Number
Serial number of the transceiver module
Manufacturing Date
Manufacturing or testing date of the transceiver module
Diagnosing transceiver modules
The switch provides the alarm function and digital diagnosis function for transceiver modules. When a
transceiver module fails or is not operating normally, you can check the alarms present on the transceiver