Table 17 Command output

Field Description

Slot

In standalone mode:
Slot—Slot number of a card

In IRF mode:

Slot—Slot number of a card on the specified member switch in the format of

member ID/slot number

Sensor

Temperature sensor:

hotspot—Hotspot sensor

inflow—Air inlet sensor

outflow—Air outlet sensor

Temperature Current

temperature

Lower limit

Lower temperature threshold.

WarningLimit

Warning temperature threshold

AlarmLimit

Alarming temperature threshold

ShutdownLimit Shut-down

temperature

threshold (currently not supported)

Isolating a card and locating card faults

When the switch detects a card failure or upgrades a logic of the CPU daughter card on a card, you can
isolate the faulty card or the CPU daughter card to prevent it from forwarding data packets. This

operation allows for convenient on-site fault location or upgrading while causing no interference on the

operation of the system and services of other cards.

Configuration guidelines

The active MPU cannot be isolated. If the Standby MPU is isolated, the load mode of the active MPU
becomes load-single.

Before upgrading a logic of the line card, keep the line card offline.

No other commands but the test diag-offline command can be executed for an isolated card.
Otherwise, the configuration cannot take effect. After isolating a card, you can use the test

diag-offline command to collect the fault location information of the card.

When you execute the test diag-offline command, the path where the fault detection information is
saved is also displayed following the fault detection information on the terminal. For example, you
can see flash:/diag_slot3_20080522_103458.txt.

Use the display device command to view whether a card is isolated, or, whether the card is in the
offline state.

Deliver the fault detection information to the professional technical engineers.

Configuration procedure

To isolate a card and locate card faults: