4.10.3 Structured Working, CRCs Enabled

In this case, the CRCs are checked and errored blocks are indicated back across the user interface
by use of the E bits.

This is the least ambiguous mode of operation from a performance monitoring point of view because
each transmission section is covered by its own independent CRC check.

To set up this configuration, go to the “Configuration > User Port” Menu and select
Rx

Unframed

(

)

Rx

Framed

(*)

Rx

CRC4

[X]

Tx TSO Transparent

( )

Tx TSO Generate

(*)

Tx

CRC4 [X]


In this mode of operation, the test loop activation messages defined in ETS 300 233 are passed to
and from the LT over the V3 interface.

CRC4

CRC4

NT1

LT

TE

CRC4G

Tx

FAW

A

SA4
SA5
SA6
SA7
SA8

TS0

Rx

CRC4M

CRC4G

Tx

TS0

Rx

CRC4M

FAW

A

SA4
SA5
SA6
SA7
SA8

HDSL

CRC6

CRC4G

Tx

FAW

A

SA4
SA5
SA6
SA7
SA8

TS0

Rx

CRC4M

CRC4G

Tx

TS0

Rx

CRC4M

FAW

A

SA4
SA5
SA6
SA7
SA8

HDSL

CRC6

ET

T

V3

E

E

E

E

Figure 6 : Structured Working, CRCs Enabled