2 heartbeat, 15 cob ids, 16 status led (to cia dr-303-3) – ifm electronic JN2100 v.2.0 User Manual
Page 23

UK
Inclination sensor JN
23
7.14.2 Heartbeat
Heartbeat is a failure monitoring mechanism which needs no RTR telegrams�
The sensor cyclically transmits a heartbeat message which contains the device
status� The master can monitor these telegrams� Heartbeat is activated as soon
as a value greater than "0" is entered in the register heartbeat interval time
(1017h)�
Heartbeat has a considerable influence on the bus load of the CANopen network - but generates a
bus load which is only half as high as node guarding / life guarding�
7.15 COB IDs
The CAN identifiers of the communication objects are determined according
to the pre-defined connection set with every reset (communication, application
and hardware reset) depending on the set node ID (2000h)�
Communication object
Calculation of the COB ID
Default value (node ID = 10)
NMT0 h
0h
SYNC
80h
80h
EMCY
80h + node ID
8Ah
TPDO1
180h + node ID
18Ah
Default SDO
(Client
→
server)
580h + node ID
58Ah
Heartbeat
700h + node ID
70Ah
7.16 Status LED (to CiA DR-303-3)
The integrated LEDs indicate the current device status (Run LED, green) and CAN
communication errors (error LED, red)�
LED
Description
Green
Off
The device is in the state "reset" or no power supply is available
Flashing
The device is in the state "pre-operational"
Brief lighting once
The device is in the state "stopped"
On
The device is in the state "operational"
Red
Off
No error
Brief lighting once
Error counter
The CAN controller has reached or exceeded its warning limit
Brief lighting twice
The device has detected the failure of the guarding master
(node guard event)
On
The device is in the state "bus off"