Settings and configuration, 5a 5b 7a 7b, 63b 3a – American Time SiteSync IQ User Manual
Page 49

49
© American Time
SiteSync IQ Installation Manual
Settings and Configuration
Glossary
Appendix
Troubleshooting
Clock
Installation
System Contr
oller
Installation
Intr
oduction
The Config Menu offers the ability to change several settings for the AllSync IQ Master.
Press
P6 and enter your service lock to access the Configuration Menu.
w
Manage Locks: From Config Menu press
1
• a. User Lock. Press:
1
and enter a new 4 digit User Lock OR
Press 0000 to disable this feature.
User Lock
• Press
O
n
Note: User Lock is the user security level used for accessing time/date
and event menus.
• b. Service Lock. Press:
2
and enter a new 4 digit Service
Lock or enter 0000 to disable this feature.
Service Lock:
• Press
O
n
Note: Service Lock is the service security level used for accessing
System Controller configuration menus.
x
Quiet Mode: From the Config Menu press
2
This feature is used to turn Quiet Mode ON or OFF. Quiet Mode limits the
number of transmissions from the system controller.
• Time messages transmit at HH:07:30 and HH:08:00 every
hour, and every 90 seconds between the times of 12:00:00 AM
and 6:00:00 AM.
• Time messages transmit every 30 seconds between 1:49:00-
2:00:00 and 7:49:00-8:00:00 AM and PM.
y
Time Sync Priority: From the Config Menu press
2
This feature is used to determine the priority of time synchronization of
the System Controller. This screen only displays the sync options that your
System Controller supports.
• a. Press the number that corresponds to your time sync
priority
• b. Enter the minutes and seconds that the System Controller
should attempt to synchronize each hour to the time sync
option chosen.
z
Clock Code: From the Config Menu press
3
This feature is used to set the clock code for wired clock circuits.
• a. Enter the clock code using the keypad
• b. Press
O
Clear/Restore: From the Config Menu press
4
This feature allows for the deletion of all events or restoration of the
System Controller to factory defaults.
• a. Press
2
to delete all events or
0
to cancel.
• b. Press
1
to restore factory defaults or
0
to cancel.
Config Menu
Time Sync Priority
2=Ethernet
Ok=Done
Config Menu
Time Sync Priority
Set to Ethernet
At 04:15
OK=Done
Config Menu
Clear All Events
1=Confirm
0=Cancel
Config Menu
Restore Factory
Settings
1=Confirm 0=Cancel
Config Menu
Choose Service Lock:
xxxx
0000=Disable OK=Done
Config Menu
Choose User Lock:
xxxx
0000=Disable OK=Done
5a
5b
7a
7b
Config Menu
Select Clock Code
01
OK=Done
6
3b
3a
Config Menu
Quiet Mode
1=ON
2=OFF
4