Wired clock circuit option, Wired clock circuit installation – American Time SiteSync IQ User Manual
Page 24

24
©American Time
Wired Clock Circuit Option
Glossary
Appendix
Tr
oubleshooting
Clock
Installation
System Contr
oller
Installation
Intr
oduction
SiteSync IQ Installation Manual
Wired Clock Circuit Installation
To install wired clock circuits:
1. Disconnect and lock out power to the SiteSync IQ System Controller and any circuit wiring.
2. Remove the top cover from the System Controller.
a. Remove screws from each side of the cover.
b. Slide the cover up off the base of the unit.
3. Route signal circuit wires into the wiring compartment of the System Controller.
a. Remove knockout(s). See Appendix G for illustration showing knockout locations on the rear side of the unit.
b. Use copper conductors only.
c. Use strain relief connector fittings in the knockout holes to secure the wires.
d. Route the wires into the wiring compartment, leaving enough slack to make all connections to the relay terminals.
4. Connect clock wires to the circuit relay terminals
REAR OF SY
STEM C
ONTR
OLLER
COM
NO
NC
NC
COM
NO
CLOCK 1
CLOCK 2
1
2
Clock Circuit Terminals
Circuit LEDs
(red)
See Appendix I on Pages 72-76 for Clock Circuit Wiring Diagrams
MON MAR 10 2014
10:38:06 AM USCT
American Time
Status=AUTO CDMA=S