Contact closure sync installation & programming, Contact closure sync option, 43a 3b 2 – American Time SiteSync IQ User Manual
Page 21: Installing contact closure sync option, Programming procedure

21
© American Time
SiteSync IQ Installation Manual
Contact Closure Sync Option
Turn on the power to the System Controller
u
Set the SiteSync IQ System Controller to be a transmitter (Tx) of the
contact closure. Press
P9
to enter Master to Master Menu.
v
Enter User Lock. Press
O
.
w
a. Press
1
to set the SiteSync IQ System Controller to Tx.
b. Enter transmit duration in milliseconds (0-9999). Press
O
.
Example: 2,000ms=2 seconds
x
Using the keypad, set the time when the contact closure should
occur. Use
<>
to select AM or PM. Press
O
.
n
Note: Reference existing equipment instruction manual for contact closure
time. These closure time and duration settings are also used for the wireless
Master Synchronizer (optional, ATS Part # H004228).
n
Note: Wireless Master Synchronizer transmissions round uup to the
nearest second. Example: 2,005ms = 3 seconds
n
Important Note! The Sync Time set in Step 4 must be the same for
both units.
Turn on the power to the System Controller
u
To set the SiteSync IQ System Controller to be a receiver (Rx) of the
contact closure. Press
P9
to enter Master to Master Menu.
v
Enter User Lock. Press
O
.
w
a. Press
2
to set the SiteSync IQ System Controller to Rx.
x
Using the keypad, set the time when the existing equipment
performs a contact closure. Use
<>
to select AM or PM.
Press
O
.
n
Note: Reference existing equipment instruction manual for contact closure time.
Comm Menu MTM Sync
Transmit Duration:
50 ms
OK=Done
Comm Menu MTM Sync
Master to Master:
1=Tx
3=Off
2=Rx
Comm Menu MTM Sync
Sync Time:
12:00:00 AM
<>AM/PM
OK=Done
Comm Menu
Enter User Lock:
____
PROG=Exit OK=Enter
4
3a
3b
2
Existing Equipment Providing 2 Wire Synchronization
SiteSync IQ System Controller providing 2 Wire
Synchronization
(refer to screen shots above)
Installing Contact Closure Sync Option
This option allows a SiteSync IQ System Controller to be synchronized with existing equipment with a contact closure. This type of
synchronization can also be implemented between two SiteSync IQ System Controllers.
existing equipment
Transmitting IQ System Controller
COM
NO
NC
NC
COM
NO
NO
COM
COM
NO
NO
COM
NO
COM
NO
COM
CLOCK 1
CLOCK 2
BELL 1
BELL 2
BELL 3
BELL 4
BELL 5
BELL 6
NO
COM
Input
Contact Closure
Output (Circuit 6)
Note: Circuit 6 will not
be operable for use as
a signal circuit when
Tx synchronization is
enabled.
Glossary
Appendix
Troubleshooting
Clock
Installation
System Contr
oller
Installation
Intr
oduction
existing equipment
existing equipment
Rx IQ System Controller
Transmitting IQ System Controller
surge protector switch
NC
NC
CO
M
NO
NO
CO
M
CO
M
NO
NO
CO
M
NO
CO
M
NO
CO
M
CL
OCK 2
BELL 1
BELL 2
BELL 3
BELL 4
BELL 5
BELL 6
NO
CO
M
Input
Contact Closure
Output
Input Connection
1
2
3
Programming Procedure
This option uses the existing system with contact closure
(i.e. Phone/Intercom System, Master Clock, Synchronizer,
etc.) to synchronize a SiteSync IQ System Controller. Connect
wiring as shown in the diagram at right.
This option uses a SiteSync IQ System Controller to sync existing
equipment supporting contact closure input. Connect wiring as shown in
the diagram below.
MON MAR 10 2014
10:38:06 AM USCT
American Time
Status=AUTO ETH=Y