Ethernet Tab:
The Ethernet Tab contains the network settings for the SiteSync IQ system controller.
Figure 12
1. Ethernet Enable: This allows the user to distinguish if the SiteSync IQ system controller should be a client, server, or both.
2. DHCP: When this box is checked, the device will automatically obtain an IP address from a DHCP server. The address
received will be displayed in the Unit IP Address boxes.
n
Note: If no DHCP address is received, the device will default to 192.168.10.10. In this situation, directly connect an
Ethernet patch cable from the system controller to a computer that is on the same Subnet.
Example: Set the connecting
computer IP address to 192.168.10.11. See your Network Administrator if you do not know how to do this. More information
is also available in the Ethernet troubleshooting section
3. Unit IP Address: This displays the IP address of the SiteSync IQ system controller. These boxes are grayed out if DHCP is
enabled and can only be changed if the DHCP box is unchecked. After changing all IP fields in the Ethernet Tab, press
the
Update button to save the configuration.
4. Time Server IP Address: This displays the IP address of the time server. After changing this field, press the Update button.
This is referred to Ethernet 1 which is displayed under the General Tab, Time Last Set: (Source Ethernet 1).
5. Alt. Time Server IP Address: This displays an alternate IP address of a time server. After changing this field, press the
Update button. This is referred to Ethernet 2 which is displayed under the General Tab, Time Last Set: (Source
Ethernet 2).
6. Subnet Mask: This displays the Subnet Mask of the Site Sync IQ system controller. After changing all IP fields in the
Ethernet Tab, press the Update button to save the configuration.
7. Gateway IP: This displays the assigned Gateway IP. After changing all IP fields in the Ethernet Tab, press the Update
button to save the configuration.
8. MAC Address: This displays the MAC address of the SiteSync IQ system controller. This field cannot be changed in
Remote Connect.
9. Port Number: This port number is defaulted to 80 so that Site Sync IQ system controller can be displayed. This enables the
web server.
10.
History: This displays a history of the Ethernet activity to and from the SiteSync IQ system controller. This can be reset by
pressing the Reset Packets Rx/Tx button.