© American Time

AllSync Plus Clock Installation

& Operation Manual

Glossary

Appendix B LED

Illumination

Appendix A

Specifications

Tr

oubleshooting

General

Operation

Installation

Intr
oduction

Installation

Metal Square Double Dial Clock Installation

Warning:

The AllSync Plus metal square double dial clock should be mounted according to these instructions to

meet UL clock listing.

1. Remove the AllSync Plus square metal double dial clock from

packaging.

2. Remove box plate from clock by removing acorn nuts at the base of the

clock. Pull wall wiring through plate hole and attach to electrical box.

3. Using UL approved wire nuts, make connections between flying leads

and wiring inside back box.

a. Black wire should be connected to hot (run) wire from the master.

b. Red wire should be connected to the correction line from the

master clock.

c. White wire should be connected to the neutral line.

d. Green wire should be connected to earth ground.

Note: All wiring connections should be made in accordance to local and

national electrical codes

4. Bundle wires inside electrical box.


5. Connect clock to box plate using acorn nuts removed in step 2.