Interlogix TVE Series User Manual
Page 30

26
TVE-400/800-1600 H.264 IP Video Encoder User Manual
Under
Alarm Linking
check one of more of the desired the response
methods:
- Audible warning: Trigger an audible beep when an alarm is detected
- Notify surveillance center: Send a notification or alarm signal to remote
alarm host when an event occurs. The alarm host refers to the computer
installed with remote client software
- Send e-mail: Send an e-mail with alarm information to a user or users
when an event occurs.
Under
Trigger Alarm Output
select the channel to trigger an external alarm
output when a motion detection event occurs
. See “To set up an alarm
output” below on how to set up an external alarm output.
Select the channel to trigger recording when a motion detection event occurs.
7. Click
Save
to save settings
.
To configure an alarm output:
1. Click
Device
Configuration
>
Alarm Settings
>
Alarm Output.
The Alarm
Output window appears.
2. Select an alarm output.
3. Select a time out option.
The time out setting lets you define how long a signal remains active after the
alarm has ended. Select a time out option: 5, 10, and 30 seconds, 1, 2, 5, and
10 minutes, and Manual stop. If “Manual stop” is selected, the alarm output
will stop only when the alarm input stops.