39
●
●
●
●
●
Chapter 4
Parameter
Name
Parameter
Number
Description
Steady Time
60.0
Time from when the target weight is reached (relay
triggered) to when the weight first remains within the
capture tolerance for the programmed number of update
periods, update time.
Unit of time is in seconds.
Cycle Time
61.0
Time form the start to the end of the fill/dispense cycle
Unit of time is in seconds.
Stable Time
62.0
Time from the start of the fill cycle to the flow rate
becoming stable. Unit of time is in seconds.
Fast Setpoint
Time
63.0
Time from the start of the fill cycle to when the relay on
the fast channel (relay A) changes state.
SlowSetpoint
Time
64.0
Time from the start of the fill cycle to when the relay on
the slow channel (relay B) changes state.
Averaged
preact value
65.0
Averaged preact value
Dynamic Output Table Description
The following commands will enable the user to read and write the parameters of the
1756 nDF during a fill cycle. These commands allow multiple parameter values and
associated functions to be modified within a single command.
See the “overview of Relay Operation” section to determine the correct Mode of
Operation value listed in the dynamic output table.
Dynamic output table format
Output table
offset
Content
0
Command – START, RESTART, SET, and STOP
1
Mode of operation (weigh scale 1)
2
Target weight TA for relay RA
3
Preact value PA for relay RA
4
Target weight for relay RB
5
Preact value for relay RB
6
7
8
Command – START, RESTART, SET, and STOP
9
Mode of operation (weigh scale 2)
10
Target weight TA for relay RA
11
Preact value PA for relay RA
12
Target weight for relay RB
13
Preact value for relay RB
14
15