Dot Matrix Display
Four 3x7 dot matrix displays provide individual status on the relays assigned to each
weigh scale channel.
The three operational states are defined in the following table.
Display
Comment
_
Not Active, OPEN
A
Active, CLOSED
X
Not being used
Setting Up Communications
Configuring the HI 1756-nDF Dispenser Filler Module in the RSLogix
5000 for ControlLogix with the HI 1756-nDF Module Add on Profile
To set up communications between the ControlLogix processor and the dispenser/Filler
Control module using the Add on Profile (AOP), you will need to do the following in
RSLogix 5000.
Step 1. Download the AOP files from the Hardy Process Solutions web site,
hardysolutions.com and install.
Note:
If a password is requested use hi1756 (all lower case).
Step 2. Under the project, right click on the I/O Configuration and from the list box
select “New Module”. The “Select Module Type” dialog box appears.
Step 3. Scroll down and find the “Hardy” modules and expand this category. Select the
HI 1756-nDF module and click on the OK button. The module properties dialog
box appears.