set control TTL output 1 signal duration time in seconds (0-255,5)
set control TTL output 2 signal duration time in seconds (0-255,5)
I
set Device ID for Network Receiver (0-999)
set tag redundancy buffer time in tenths of seconds (0-255, 125)
set time between tag read outputs in tenths of seconds (0-255, 13)
add new Device ID or Status Code to Valid ID list (0-255, max 34)
delete a Device ID or Status Code to Valid ID list (0-255, min. 1 entry)
add new Device ID or Status Code to Valid Wiegand ID list (0-255, max. 34)
delete a Device ID or Status Code to Valid Wiegand ID list (0-255, min. 1 entry)
10c
turn on TTL output 1 now
11c
turn on TTL output 2 now
12c
set Wiegand alarm output to OFF
13c
set TTL output 1 alarm flag to OFF
14c
set TTL output 2 alarm flag to OFF
15c
set Wiegand output to ON
16c
set TTL output 1 valid read flag to OFF
17c
set TTL output 2 valid read flag to OFF
18c
set tag read serial output to ON
19c
set Wiegand Activator ID filter to ON
20c
set Wiegand/TTL output interrupts to ON
21c
set serial output to the long format (RRRAAAFFFTTTTT)
22c
set serial diagnostics output to OFF
23c
set serial data rate to 4800 baud
24c
set serial data rate to 9600 baud
25c
set serial data rate to 19200 baud
26c
set Wiegand alarm output to ON
27c
set TTL output 1 alarm flag to ON
28c
set TTL output 2 alarm flag to ON
29c
set Wiegand output to OFF
30c
set TTL output 1 valid read flag to ON
31c
set TTL output 2 valid read flag to ON
32c
set tag read output to OFF
33c
set Wiegand Activator ID filter to OFF
34c
set Valid ID list to default values (per V5 list)
35c
set Wiegand/TTL output interrupts to OFF
36c
set serial output to short format (AAAFFFTTTTT)
37c
clear Valid ID list (except 127)
38c
return and display current configuration data
39c
set serial diagnostics output to ON
40c
return and display Supervisory data
41c
enable the Wiegand ID list
42c
disable the Wiegand ID list
43c
clear Valid Wiegand ID list (except 127)
44c
set Valid Wiegand ID list to default values (per V5 list)