Axcess Network Receiver Installation Guide User Manual
Page 17

© 2002, AXCESS Inc.
750.001.005 R0000
17
Responding to Activator IDs
The Receiver will
only output Tag data via the serial port if it
contains a valid Activator ID.
By default, The Network Receiver accepts Tag data from
Activators with the following IDs:
0
3
13
14
21
22
24
27
33
34
44
47
52
55
57
58
69
70
72
75
80
83
93
94
100
103
105
106
113
114
124
127
254
255
Figure 5 Default Activator IDs
Editing Activator IDs within the Receiver
Use the following commands to add, delete and reset the
Activator ID numbers within the Receiver:
Command Action
37c
Remove all accepted Activator IDs
(Receiver will still pass default ID 127)
34c
Reset the list to the valid Activator ID numbers
When editing the Activator IDs within the Receiver, you may
observe the following error codes.
Code
Reason
04
Trying to delete an ID that has not been
programmed
03
Trying to delete all IDs. Must be at least one ID.
02
Trying to enter more than 34 IDs – the max.
(Delete some Activator IDs on the list to make room)
01
Duplicate entry